Carrier furnace: Code 43 — Low-Heat Pressure Switch Open in High Heat
Try DIY first, then call a pro
What does code 43 mean on a Carrier furnace? On the two-stage variable-speed control, a call for high heat closed the high-heat pressure switch but the low-heat switch stayed open. The control shuts down, stops the inducer, keeps the gas off, and retries after 2 minutes. Official checklist: low inlet gas pressure (if LGPS used), plugged condensate drain, pressure switch wiring, water or sag in the vent piping, a stuck-open low-heat switch, disconnected or obstructed pressure tubing.
GOOD NEWS: THE FIRST CHECKS ARE FREE AND TAKE MINUTES.
Try these first — in this order
Drain trap, vent pipe slope, and the pressure tubing to both switches.
Switch testing and a wiring check, since the two switches are easy to cross. DIY part cost: $30–60 — a pro visit for this class of fault typically runs $150–350.
What causes it (in order of likelihood)
- Plugged condensate drain, or water pooling in a sagging vent pipe DIY-CHECKABLE
- Disconnected or obstructed pressure tubing DIY-CHECKABLE
- Low-heat pressure switch stuck open, or the two switches miswired TECH
- Low inlet gas pressure (if LGPS used) TECH
Parts referenced by this code
Always match parts against your model's parts list — part numbers vary within a series.
Applies to
58MVP (Series 170/180) · 58MVB · 58UVB
Different Carrier generations use different code maps. If your series isn't listed, don't assume this meaning — check your blower-door label.
Verified against Carrier 58MVP/58MVB/58UVB Troubleshooting Guide (58-06T), p.8/30 — “LOW-HEAT PRESSURE SWITCH OPEN WHILE HIGH-HEAT PRESSURE SWITCH IS CLOSED – Check for: Low inlet gas pressure (if LGPS used). Plugged condensate drain. Improper pressure switch wiring. Water in vent piping, possible sagging pipe. Stuck open low-heat pressure switch. Disconnected or obstructed pressure tubing.”
Verified against Carrier 58MVP/58MVB/58UVB Troubleshooting Guide (58-06T), p.30 — “If the high heat pressure switch HPS makes and the low heat pressure switch LPS is still open the variable speed furnace control starts flashing status code 43, shuts unit down, and waits 2 minutes before restarting the heating cycle.”
Verified against Carrier 58MVB Service and Maintenance Instructions (58MVB-2SM), p.17 — “Check for: - Low-heat pressure switch stuck open. - Disconnected or obstructed pressure tubing. - Improper pressure switch wiring. - Low inlet gas pressure (if LGPS used). - Plugged condensate drain. - Water in vent piping, possible sagging pipe.”
Last verified 2026-09-05 · how we verify
Related Carrier fault codes
These codes use the same status led — two-stage variable-speed (58mvp / 58mvb / 58uvb) system.
| Pattern | Meaning |
|---|---|
| Code 42 — Inducer Motor Fault | |
| Code 41 — Blower Motor Fault | |
| Code 32 — Low-Heat Pressure Switch Did Not Close or Reopened | |
| Code 25 — Model Selection or Setup Error |