RHEEM DIAGNOSTIC REFERENCE 17 VERIFIED CODES

Rheem furnace error codes

This chart covers the two-digit display on Rheem R801SA / 801S downflow single-stage 80% furnaces, as documented in installation manual 92-24161-143-14. Each digit shows for one second, followed by a half-second blank, so 33 reads as a three and then a three, not as counted flashes. A code records what the control observed. It does not name a failed part. Several codes lead to lockout, and some, including 14 and 33, mean the furnace should stay off until a technician investigates.

Jump to the code table · All furnace codes

Before you touch anything: the six signs that mean stop troubleshooting and call a pro →

How to read the 801S downflow display

The control shows numbers on a seven-segment display, not blink counts. 0 is standby, C is compressor operation for cooling or heat-pump heat, H is gas heating and F is continuous fan. None of these is a fault, and H does not prove warm air is being delivered. When paired codes are shown, the top bar of the display lights for half a second between them. A separate amber flame LED is off with no flame, stays on with normal flame, flashes one to four times per second for weak flame and flashes rapidly for unexpected flame.

What this chart covers and excludes

It covers the 13 fault codes in the main table of downflow manual 92-24161-143-14 (December 2017), which also describes a PSC blower motor. Rheem's official R801SA index confirms that document's authorship and revision. The chart itself was read in an exact copy hosted on ManualsLib, not on a Rheem site, and no second numeric chart corroborates it. Upflow/horizontal, two-stage, modulating, EcoNet, 801T, 801V and older 1–5 blink controls are excluded, as are water-sensor codes 58 and 59 from generic flowcharts.

Rheem 801S downflow fault codes (manual 143-14)

Rheem furnace codes and supported model families
Code or flash pattern Meaning Model family Details
10Two-digit display: 10, alternating with a reason code One-hour lockout

Code 10 means the control has entered a one-hour soft lockout. Four failed ignitions, five flame losses in one heat call, unexpected flame or a dead-blower detection can cause it, and the reason code alternates with 10.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
11Two-digit display: 11, alternating with 10 at lockout Failed ignition

Code 11 records failed ignition. After four consecutive failed ignition attempts, the display alternates 10 and 11 and the furnace enters a one-hour lockout.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
12Two-digit display: 12 (separate amber flame LED may flash) Low flame signal

Code 12 means the control is sensing a weak flame signal. The code reports the signal level only; it does not by itself prove the flame sensor is dirty.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
13Two-digit display: 13, alternating with 10 at lockout Flame lost

Code 13 means the burner lit and the flame was then lost. If this happens five times in one heat call, 10 and 13 alternate and the furnace locks out for one hour.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
14Two-digit display: 14, may alternate with 10 (amber flame LED may flash rapidly) Unexpected flame

Code 14 means the control sensed flame when none should be present. 14 and 10 can alternate, and the one-hour lockout timer starts only once the unexpected flame is no longer detected.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
20Two-digit display: 20 Twinning fault

Code 20 reports a twinning fault: a problem with the circuit or configuration used when two furnaces are linked to operate together. It is not a burner or flame fault.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
22Two-digit display: 22 Main limit or HALC open

Code 22 means the main limit or the HALC is open. The limit protects against excessive outlet air temperature, so the control stops burner operation while it is open.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
26Two-digit display: 26 Line and neutral reversed

Code 26 means the control has detected reversed line and neutral polarity on the furnace's power supply. Correct polarity matters because it can affect flame sensing.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
33Two-digit display: 33 Rollout limit open

Code 33 means a manual-reset limit control, such as a flame-rollout switch, is open. A technician must identify which device opened and why before the furnace runs again.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
55Two-digit display: 55 Pressure switch closed

Code 55 means the pressure switch circuit reads closed when the control expects it open. The contacts must be open before the next heating cycle can begin.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
57Two-digit display: 57 Pressure switch open

Code 57 means the pressure switch stayed open when the control expected it closed. If it does not close within the 60-second proving period, the furnace enters a five-minute soft lockout.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
61Two-digit display: 61, may alternate with 10 or 22 Blower unable to run

Code 61 means the control has inferred a dead blower because the main limit stayed open for more than 150 seconds. It is a deduction from the limit circuit, not a direct motor test.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
93Two-digit display: 93 Internal control fault

Code 93 is a hard lockout for an internal control fault, which can include abnormal voltage persisting at the gas-valve contacts. Cycling the thermostat heat call does not clear it.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
0Single-digit display: 0 Standby

0 is the normal standby display. The control is powered and waiting for a call from the thermostat; it does not indicate a fault.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
CSingle-character display: C Compressor running

C means the compressor is running for cooling or heat-pump heating. It is a normal operating display on this control, not a fault.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
HSingle-character display: H Gas heat on

H means the control is running a gas heating call. It shows the operating mode only and does not by itself confirm that the burner lit or warm air is reaching the rooms.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details
FSingle-character display: F Continuous fan

F means the continuous fan is on. The blower runs without a heating or cooling call, so register air will be close to room temperature.

R801SA / 801S downflow single-stage 80% furnace with PSC motor View details

Not sure how to read the light?

Use the interactive blink decoder — tap the pattern you see and we'll match it.