Rheem R801SA furnace code 10: One-hour lockout

10 YOUR LIGHT: TWO-DIGIT DISPLAY: 10, ALTERNATING WITH A REASON CODE — MATCH IT ABOVE

Professional repair

What does code 10 mean on a Rheem R801SA (801S downflow) furnace display? Code 10 means the control has entered a one-hour soft lockout. Four failed ignitions, five flame losses in one heat call, unexpected flame or a dead-blower detection can cause it, and the reason code alternates with 10.

Before you touch anything: the six signs that mean stop troubleshooting and call a pro →

Safe checks before calling

Write down the full sequence, including the code shown with 10, and note whether ignition never starts or starts then stops. Leave panels in place.

Still showing the code? See every cause ↓ Get repair quotes near you

A technician should identify which paired code caused the lockout, then test ignition, flame current, gas pressure, blower operation and safety circuits as that code directs.

Possible causes

  1. Repeated ignition failure or repeated flame loss during heating TECH
  2. Unexpected flame sensed when the burner should be off TECH
  3. Main limit open long enough to infer a dead blower TECH

Parts for this code

No model-verified part number is listed here. Have the fault diagnosed and the correct part matched to your furnace before ordering.

Rheem furnace replacement parts
Search by your model number (on the blower-door label) for an exact match

Questions about this code

What does code 10 mean on a Rheem R801SA (801S downflow) furnace display?

Code 10 means the control has entered a one-hour soft lockout. Four failed ignitions, five flame losses in one heat call, unexpected flame or a dead-blower detection can cause it, and the reason code alternates with 10.

How do I fix Rheem R801SA furnace code 10?

Treat 10 as a pointer, not the fault itself. The repair follows the code shown alongside it. If that code is 14, keep the furnace off and call for service. Waiting out the hour or power cycling does not fix the underlying cause.

How much does it cost to fix Rheem R801SA furnace code 10?

Cost depends on the paired code, not the lockout. Diagnosis time covers reading that code and testing the related circuit; parts and labor follow only if a fault is confirmed.

Applies to

R801SA / 801S downflow single-stage 80% furnace with PSC motor

Different Rheem generations use different code maps. If your series isn't listed, don't assume this meaning — check your blower-door label.

Verified against Installation Instructions for Downflow Single Stage Gas Furnaces, p.34

Verified against Rheem 801S Series Installation Instructions — OEM143-14 mirror, p.34

Verified against Rheem 801S Series Installation Instructions — OEM143-14 mirror, p.35

Last verified 2026-10-07 · page updated 2026-10-07 · how we verify