HVAC●FAULTS
YORK DIAGNOSTIC REFERENCE YORK TM9E SINGLE-STAGE ECM TRI-COLOR LED CONTROL DOC YORK-TM9E-7-RED-FLASH

York TM9E furnace 7 red flashes: Ignition Failure

YOUR LIGHT: RED LED: 7 FLASHES, THEN 2-SECOND PAUSE — MATCH IT ABOVE

Professional repair

What do 7 red LED flashes mean on a York TM9E furnace? The furnace made three ignition trials without establishing flame. The control then locks out for one hour and retries automatically.

Gas / CO warning

This condition involves the gas or combustion side. If you smell gas or a CO alarm sounds: leave, then call your gas utility. Diagnostic info here is reference — combustion repairs are for licensed technicians. All six emergency signs →

See what causes this code ↓ Get repair quotes near you

A technician checks gas pressure, the gas valve, ignitor, flame sensor, burners and wiring. None of these are homeowner tasks, including sensor cleaning or gas adjustments.

Possible causes

  1. Low or no gas pressure, or a gas valve problem TECH
  2. Ignitor or flame sensor fault, both listed by York TECH
  3. Wiring or burner problem found during technician diagnosis TECH

Parts for this code

No model-verified part number is listed here. Have the fault diagnosed and the correct part matched to your furnace before ordering.

York furnace replacement parts
Search by your model number (on the blower-door label) for an exact match

Questions about this code

What do 7 red LED flashes mean on a York TM9E furnace?

The furnace made three ignition trials without establishing flame. The control then locks out for one hour and retries automatically.

How do I fix York TM9E furnace 7 red flashes?

Arrange service and let the technician work through the gas supply and ignition components. A successful retry after the 1-hour lockout does not show the problem is fixed, so avoid forcing restarts in the meantime.

How much does it cost to fix York TM9E furnace 7 red flashes?

Charges reflect diagnosis across several possible causes. A gas-supply issue, ignitor, sensor or valve each involves different parts and fitting time.

Applies to

TM9E

Different York generations use different code maps. If your series isn't listed, don't assume this meaning — check your blower-door label.

Verified against YORK TM9E Series Installation Manual — Single Stage ECM Residential Gas Furnaces, p.34

Last verified 2026-10-07 · page updated 2026-10-07 · how we verify

Related York furnace codes

These codes use the same york tm9e single-stage ecm tri-color led control system.

See all York furnace fault codes →