Bryant furnace: Code 13 — Limit Circuit Lockout
Try DIY first, then call a pro
Bryant furnaces share the Carrier control platform — this code table applies to the equivalent Bryant models. Confirm against your unit's panel label.
What does code 13 mean on a Carrier furnace? A limit, draft safeguard, flame rollout, or blocked-vent switch stayed open longer than 3 minutes → lockout. Auto-resets after 3 hours. Root causes = see code 33.
GOOD NEWS: THE FIRST CHECKS ARE FREE AND TAKE MINUTES.
Try these first — in this order
Same first moves as code 33: filter and vents.
Recurring lockouts need heat-exchanger and venting inspection. DIY part cost: $5–25 — a pro visit for this class of fault typically runs $150–350.
What causes it (in order of likelihood)
- Everything under code 33 (airflow/vent restrictions), sustained 3+ minutes DIY-CHECKABLE
Parts referenced by this code
Always match parts against your model's parts list — part numbers vary within a series.
Applies to
58STA · 58STX · Bryant 310/311/312 系 · Payne PG8M 系
Different Bryant generations use different code maps. If your series isn't listed, don't assume this meaning — check your blower-door label.
Verified against Carrier 58STA/58STX Installation & Service Instructions (1106202L), p.37/48 — “auto-reset after 3 hours. See code 33”