Payne furnace code 13: Limit Circuit Lockout

YOUR LIGHT: 1 SHORT + 3 LONG FLASHES — MATCH IT ABOVE

Try DIY first, then call a pro

Payne furnaces share the Carrier control platform — this code table applies to the equivalent Payne models. Confirm against your unit's panel label.

What does code 13 mean on a Payne furnace? A limit, draft safeguard, flame rollout, or blocked-vent switch stayed open longer than 3 minutes → lockout. Auto-resets after 3 hours. Root causes = see code 33.

Before you touch anything: the six signs that mean stop troubleshooting and call a pro →

GOOD NEWS: THE FIRST CHECKS ARE FREE AND TAKE MINUTES.

Try these first — in this order

Same first moves as code 33: filter and vents.

1Check: Everything under code 33 (airflow/vent restrictions), sustained 3+ minutes
Still showing the code? See every cause ↓ Get repair quotes near you

Recurring lockouts need heat-exchanger and venting inspection. DIY part cost: $5–25 — a pro visit for this class of fault typically runs $150–350.

What causes it (in order of likelihood)

  1. Everything under code 33 (airflow/vent restrictions), sustained 3+ minutes DIY-CHECKABLE

Parts referenced by this code

Air Filter (check size on the old one)
$5–25

Always match parts against your model's parts list — part numbers vary within a series.

Questions about this code

What does code 13 mean on a Payne furnace?

A limit, draft safeguard, flame rollout, or blocked-vent switch stayed open longer than 3 minutes → lockout. Auto-resets after 3 hours. Root causes = see code 33.

How do I fix Payne furnace code 13?

Stop troubleshooting and arrange a technician visit. Don't reset any switch. If it returns, call a technician; if a CO alarm sounds, leave and call from outside.

How much does it cost to fix Payne furnace code 13?

A dirty filter may be inexpensive to correct, but recurring lockouts can call for venting, blower, or heat-exchanger inspection. The price depends on which switch opened and why.

Applies to

Payne PG8M series

Different Payne generations use different code maps. If your series isn't listed, don't assume this meaning — check your blower-door label.

Same control platform, same code: Carrier furnace code 13 · Bryant furnace code 13

Verified against Carrier 58STA/58STX Installation & Service Instructions (1106202L), p.37/48 — “auto-reset after 3 hours. See code 33”

Payne PG8M series furnaces use the Carrier 58STA/58STX control platform. No separate Payne service document is cited — confirm the code map against your unit's panel label.

Last verified 2026-07-06 · page updated 2026-10-03 · how we verify

Related Payne furnace codes

These codes use the same status led — short + long flash codes system.

See all Payne furnace fault codes →

All furnace codes