GOODMAN DIAGNOSTIC REFERENCE GMEC96 TRI-COLOR CONTROL — RED FAULT FLASHES DOC GOODMAN-GMEC96-6-RED-FLASH

Goodman furnace: Pressure Switch Cycle Lockout — 6 Red Flashes

YOUR LIGHT: 6 FLASHES — MATCH IT ABOVE

Try DIY first, then call a pro

What do 6 red flashes mean on a Goodman GMEC96 furnace? The pressure-switch signal dropped out often enough during a heat cycle that the GMEC96 control locked the furnace out. This points to an intermittent draft problem rather than a steady switch state.

GOOD NEWS: THE FIRST CHECKS ARE FREE AND TAKE MINUTES.

Try these first — in this order

With power off, inspect the hose, outdoor vent ends, and condensate trap for an obvious blockage.

1Check: Loose, cracked, wet, or partially blocked pressure-switch hose
2Check: Blocked intake, exhaust, or condensate drain
Still showing the code? See every cause ↓ Get repair quotes near you

Recurring six-flash lockouts require draft-pressure and inducer testing. DIY part cost: $25–60 — a pro visit for this class of fault typically runs $150–350.

What causes it (in order of likelihood)

  1. Loose, cracked, wet, or partially blocked pressure-switch hose DIY-CHECKABLE
  2. Blocked intake, exhaust, or condensate drain DIY-CHECKABLE
  3. Weak inducer or failing pressure switch TECH

Parts referenced by this code

Pressure Switch
$25–60 · Model-specific — match to your unit’s parts list

Always match parts against your model's parts list — part numbers vary within a series.

Applies to

GMEC96

Different Goodman generations use different code maps. If your series isn't listed, don't assume this meaning — check your blower-door label.

Verified against Goodman GMEC96 Service Manual, p.53

Last verified 2026-07-06 · how we verify