Goodman GMEC96 furnace 8 red flashes: External Lockout From Recycles

YOUR LIGHT: 8 FLASHES — MATCH IT ABOVE

Try DIY first, then call a pro

What do 8 red flashes mean on a Goodman GMEC96 furnace? The burners lit, but the control lost flame proof repeatedly and used up its recycle limit. That is different from seven flashes, where ignition never completed successfully.

Before you touch anything: the six signs that mean stop troubleshooting and call a pro →

Homeowner checks for Goodman GMEC96 furnace 8 red flashes

This is a limited outdoor observation check, not a complete furnace repair. If you smell gas or a carbon monoxide alarm sounds, leave the home right away without operating any switches, then call the gas utility or 911 from outside. Never bypass a safety switch or reset the furnace over and over.

  1. Turn the furnace off

    Turn off the furnace at the thermostat and its nearby power switch before checking the vent ends. Keep the furnace cabinet closed.

  2. Find the vent ends from ground level

    Locate the furnace intake and exhaust pipe ends where they leave the house. Only check ends you can see and reach while standing on the ground. Do not climb a ladder or go onto the roof.

  3. Clear loose snow or leaves by hand

    If it is safe to stand there, brush away loose surface snow or leaves from around the openings by hand, without tools. Do not reach into the pipes, chip at ice, or remove or modify any pipe, cap, or screen.

  4. Stop and call if anything else is wrong

    Leave the furnace off and call a technician if you find ice, a nest, a damaged pipe, or anything you cannot clear safely by hand. After clearing only loose surface snow or leaves, restore power and observe one heating cycle. If the code returns, turn the furnace off and arrange service.

Still showing the code? See every cause ↓ Get repair quotes near you

Repeated flame loss needs combustion, gas-pressure, and flame-current measurements. DIY part cost: $8–15 — a pro visit for this class of fault typically runs $150–350.

What causes it (in order of likelihood)

  1. Weak or unstable flame-sensor signal DIY-CHECKABLE
  2. Intermittent gas pressure, venting, or burner problem TECH

Parts referenced by this code

0130F00010 — Flame Sensor
$8–15 · also sold as B1172606

Always match parts against your model's parts list — part numbers vary within a series.

Questions about this code

What do 8 red flashes mean on a Goodman GMEC96 furnace?

The burners lit, but the control lost flame proof repeatedly and used up its recycle limit. That is different from seven flashes, where ignition never completed successfully.

How do I fix Goodman GMEC96 furnace 8 red flashes?

From ground level, check the outdoor vent ends and clear loose snow or leaves by hand if safe. Flame sensor, gas pressure, and combustion measurements are for a technician.

How much does it cost to fix Goodman GMEC96 furnace 8 red flashes?

Cost depends on whether the flame signal, gas pressure, venting, or burner is responsible. Combustion and flame-current measurements are needed before a price is clear.

Applies to

GMEC96

Different Goodman generations use different code maps. If your series isn't listed, don't assume this meaning — check your blower-door label.

Verified against Goodman GMEC96 Service Manual, p.53

Last verified 2026-07-06 · page updated 2026-10-03 · how we verify