HVAC●FAULTS
LENNOX DIAGNOSTIC REFERENCE LENNOX ML193UHE WITH IGNITION CONTROL 103217-03 DOC LENNOX-ML193UHE-9-FLASH

Lennox ML193UHE furnace 9 red flashes: Pressure Switch Not Proven

YOUR LIGHT: RED LED: 9 FLASHES, THEN 3-SECOND PAUSE — MATCH IT ABOVE

Professional repair

What do 9 red LED flashes mean on a Lennox ML193UHE with ignition control 103217-03? During a heat demand, the pressure switch either did not close or opened after closing. It is part of the pressure-proving circuit tied to the combustion-air inducer and venting.

Gas / CO warning

This condition involves the gas or combustion side. If you smell gas or a CO alarm sounds: leave, then call your gas utility. Diagnostic info here is reference — combustion repairs are for licensed technicians. All six emergency signs →

See what causes this code ↓ Get repair quotes near you

A technician should check the inducer, vent, condensate drainage and pressure-proving circuit. The code does not prove the switch itself failed, and the switch must not be bypassed or adjusted.

Possible causes

  1. Inducer, venting or condensate problem affecting pressure proving TECH

Parts for this code

No model-verified part number is listed here. Have the fault diagnosed and the correct part matched to your furnace before ordering.

Lennox furnace replacement parts
Search by your model number (on the blower-door label) for an exact match

Questions about this code

What do 9 red LED flashes mean on a Lennox ML193UHE with ignition control 103217-03?

During a heat demand, the pressure switch either did not close or opened after closing. It is part of the pressure-proving circuit tied to the combustion-air inducer and venting.

How do I fix Lennox ML193UHE furnace 9 red flashes?

Book service and report the flash count and whether the furnace stopped before or after it began heating. Leave pressure hoses, switches and vent connections untouched. If the code changes to ten flashes, the control has entered pressure-switch Watchguard.

How much does it cost to fix Lennox ML193UHE furnace 9 red flashes?

Cost follows the diagnosis: an inducer, venting, drainage or switch problem each involves different parts and labor. A pressure-switch code alone does not justify replacing the switch.

Applies to

ML193UHE

Different Lennox generations use different code maps. If your series isn't listed, don't assume this meaning — check your blower-door label.

Verified against Lennox ML193UHE Installation Instructions, p.39

Verified against Lennox ML193UHE Unit Information / Service Literature, p.9

Last verified 2026-10-07 · page updated 2026-10-07 · how we verify

Related Lennox furnace codes

These codes use the same lennox ml193uhe with ignition control 103217-03 system.

See all Lennox furnace fault codes →