HVAC●FAULTS
PAYNE DIAGNOSTIC REFERENCE STATUS LED — SHORT + LONG FLASH CODES DOC PAYNE-22

Payne furnace code 22: Abnormal Flame-Proving Signal

YOUR LIGHT: 2 SHORT + 2 LONG FLASHES — MATCH IT ABOVE

Safety issue — act now

Payne furnaces share the Carrier control platform — this code table applies to the equivalent Payne models. Confirm against your unit's panel label.

What does code 22 mean on a Payne furnace? Flame is proved while the gas valve is de-energized; the inducer runs until the fault clears. Official causes: a leaky or stuck-open gas valve.

Gas / CO warning

This condition involves the gas or combustion side. If you smell gas or a CO alarm sounds: leave, then call your gas utility. Diagnostic info here is reference — combustion repairs are for licensed technicians. All six emergency signs →

See what causes this code ↓ Get repair quotes near you

Gas off at the appliance valve, same-day licensed tech. Not a DIY code. DIY part cost: $90–200 — a pro visit for this class of fault typically runs $150–350.

What causes it (in order of likelihood)

  1. Leaky / stuck-open gas valve TECH

Parts referenced by this code

Gas Valve
$90–200 · Licensed-tech part

Always match parts against your model's parts list — part numbers vary within a series.

Questions about this code

What does code 22 mean on a Payne furnace?

Flame is proved while the gas valve is de-energized; the inducer runs until the fault clears. Official causes: a leaky or stuck-open gas valve.

How do I fix Payne furnace code 22?

Stop troubleshooting. If you smell gas, leave without using switches and call the gas utility or 911 from outside. Otherwise set the thermostat to off and get same-day licensed service.

How much does it cost to fix Payne furnace code 22?

This code doesn't predict a price. Gas-valve diagnosis and repair need a licensed technician, so arrange service promptly.

Applies to

Payne PG8M series

Different Payne generations use different code maps. If your series isn't listed, don't assume this meaning — check your blower-door label.

Same control platform, same code: Carrier furnace code 22 · Bryant furnace code 22

Verified against Carrier 58STA/58STX Installation & Service Instructions (1106202L), p.37/48

Payne PG8M series furnaces use the Carrier 58STA/58STX control platform. No separate Payne service document is cited — confirm the code map against your unit's panel label.

Last verified 2026-07-06 · page updated 2026-10-03 · how we verify